| Brand Name: | CHENGFENG |
| Model Number: | CF8342 |
| Certification: | ISO,CE |
| Place of Origin: | China |
| MOQ: | 1 Set |
| Price: | US$2000-$30000 |
| Payment Terms: | T/T, Cash.L/C, D/A, D/P, Western Union, MoneyGram |
| Supply Ability: | 5 units per month |
| Delivery Time: | 10 Work Days |
| Packaging Details: | Wooden cases |
| Gas flow rate:: | 0-100L/min, measurement accuracy 2.5 grade |
| Air flow rate:: | 0-50m ³ /min, measurement accuracy ≤±0.5m ³ /min. |
| Gas tank capacity:: | ≥50kg×6 |
| Load measurement equipment:: | ±2.5% of the load value should be added |
| Furnace pressure measurement range:: | 0 to 100pa |
| Measurement accuracy:: | ≤±3pa |
| Furnace temperature:: | ±15°C |
| Company Info. |
| Dongguan Chengfeng Testing Equipment Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Scope of application: It is applicable to fire resistance tests of
building components and the fire resistance performance of
load-bearing vertical partition components.
Working voltage: AC 380V±10% 50NZ.
The furnace body: The test furnace passage is composed of bricks,
steel structures and fireproof and heat-insulating materials.
Sample size: 300mm wide × 300mm high (customizable).
The dimensions inside the furnace are approximately:
Vertical furnace: L3.2m×W2.2m×H4.0m
Horizontal furnace: L3.2m×W3.2m×H1.5.
Gas flow rate: 0-100L/min, measurement accuracy 2.5 grade.
Air flow rate: 0-50m ³ /min, measurement accuracy ≤±0.5m ³ /min.
Gas tank capacity: ≥50kg×6.
Load measurement equipment: ±2.5% of the load value should be added
(required for loading type tests).
Specimen gap measurement probe: ±0.1mm for diameter 6mm, ±0.2mm for
diameter 25mm.
Combustion system: Gas distribution system (within 10 meters),
burner nozzles (no less than 20) and regulating valves.
Combustion gas source: propane, liquefied gas.
Furnace temperature control system: Maximum sampling points of 10.
Ventilation systems and control dampers, etc.
The measurement range of radiant heat on the backfire side of the
specimen is 0 to 10W/cm ².
Furnace pressure measurement range: 0 to 100pa
Measurement accuracy: ≤±3pa.
Test temperature: The furnace temperature control meets the
requirement of T-T0=3451g (8t+1), and its temperature control
deviation
When 0min < t≤10min, d≤15%.
When 10 minutes < t≤30 minutes, d≤10%.
When T > 30 minutes, d≤5%.
Furnace temperature: ±15°C.
Internal temperature of the specimen: ±10°C.
Backfire temperature of the specimen: ±4°C.
Measurement conditions for pressure inside the furnace
Five minutes after the start of the test, the furnace should meet
the following positive pressure conditions as stipulated.
Horizontal component - On a horizontal surface 100mm below the
bottom surface of the specimen, the furnace pressure is 15pa±5pa.
Vertical component - at a height of 3 meters inside the furnace,
100mm from the surface of the test piece. The furnace pressure is
15pa±5pa.
Ten minutes after the start of the test, the furnace should meet
the following positive pressure conditions as stipulated.
Horizontal component - On a horizontal surface 100mm below the
bottom of the specimen, the furnace pressure is 17pa±3pa.
Vertical component - at a height of 3 meters inside the furnace,
100mm from the surface of the test piece. The furnace pressure is
17pa±3pa.
Furnace temperature: ±15°C, using a thermocouple with a diameter of
1mm.
Test piece backfire temperature: ±4°C, thermocouple with a wire
diameter of 0.5mm.
Armored platinum-rhodium-platinum S-value thermocouple, accuracy
grade II.
Armored nickel-chromium-nickel-silicon K value thermocouple, grade
II.
Timing range: 0 to 120 minutes. Timing accuracy: < ±1 second.
Sample temperature detection system: Maximum sampling points of 20.
Scope of application: The test furnace complies with the technical
indicators and requirements stipulated in the national standard
GB/T7633-2008 and is suitable for the fire resistance performance
test of non-load-bearing horizontal doors and roller shutters.
Main parameters
Power consumption: 6KW
Furnace pressure measurement range: 0-100Pa measurement accuracy:
≤±3Pa
Air flow rate: 0-50m³/min Measurement accuracy: ≤±0.5 m³/min
Combustion gas source: Propane, liquefied gas (provided by the
user)
Gas tank capacity: 50kg×6
Measurement range of radiant heat on the backfire side of the
specimen: 0-10W/cm ²
Pressure measurement range inside the furnace: 15Pa±5Pa;
Test temperature: Programmed temperature rise for 15 minutes from
room temperature to 718℃
30 minutes room temperature to 821℃, 60 minutes room temperature to
925℃
90 minutes room temperature to 986℃; 120 minutes room temperature
to 1029℃;
180 minutes at room temperature to 1115℃, 240 minutes at room
temperature to 1150℃.
Temperature sensor: Inside the furnace: 9 armored
nickel-chromium-nickel-silicon K value thermocouples, accuracy
grade: Class II
Backfire: 29 armored nickel-chromium-nickel-silicon K value
thermocouples, accuracy grade: Class II
Timing range: 0-240 minutes. Timing accuracy: <±1 second
External sample size: (Special specifications can be customized by
users)
The practical area of the equipment: length × width × height
(3.8×2.4×4.5)m;
Equipment weight: 4500 Kg(The test furnace needs to be installed on
site);
Gasification system: 150kg/h(optional).
ISO 9705:2003 specifies a test method for simulating a fire that
occurs in the corner of a small room. This method uses a standard
ignition source and aims to assess the impact of surface products
on the development of the fire. This method provides data on the
fire from ignition to burling-through that occurs under the
standard ignition source. ISO 9705:2003 also introduces different
measurement techniques both inside and outside the room. The ISO
9705 test in this article provides background information and
support for potential users. It provides users with technical
information on fire source testing, the heat flux of the burner in
the room, the thermal balance of the room during a fire, the types
of smoke and toxic gases produced, as well as the simulation
results of these tests. It offers users the necessary information
to help them select test steps for specific projects or
regulations.
The test method in our country is equivalent to adopting this test
method, and the developed standards are Appendix B and Appendix C
of GB 20286.
Compliant standards: ISO 9705, NFPA 266, Appendix B and Appendix C
of GB20286, etc
Technical parameters
1. 19-inch instrument frame, including oxygen, carbon dioxide and
carbon monoxide analyzers
2. The oxygen analyzer is an oxygen analyzer that detects the
oxygen concentration in the gas by measuring the changes in
paramagnetic pressure. Response time (T90) : 3.5 seconds, internal
signal processing time: less than 1 second, pressure sensor
(internal) : 50 to 200 kPa, zero drift: less than 0.5% of the
minimum range indicated on the nameplate per month, measurement
value drift: less than 0.5% of the current measurement range per
month, repeatability error: less than 1% of the current measurement
range The minimum detection limit is 1% of the current measurement
range, and the linear error is less than 1% of the current
measurement range
3. The carbon dioxide analyzer and carbon monoxide analyzer are
non-discrete infrared types. The principle is based on the fact
that gas molecules have specific infrared light absorption bands,
and they adopt the single-beam alternating infrared analysis
method. The minimum detection limit is 1% of the current
measurement range. The linear error is less than ±1% of the full
scale when measured within the maximum range. The repeatability is
less than ±1% of the minimum range indicated on the nameplate. The
response time (T90 time) is less than 30 seconds when the sample
gas flow rate is approximately 1.2L/min
4. The range of the oxygen analyzer is 0-25%, that of the carbon
dioxide analyzer is 0-10%, and that of the carbon monoxide analyzer
is 0-1%
5. A temperature controller is used to control the cold trap.
During the gas extraction process of the test, the moisture is
thoroughly removed
6. The gas sampling dual-head pump can transport the gas samples
produced during combustion to an analyzer approximately 30 meters
away
7. Data acquisition system (including operation and control
programs)
8. The acquisition board card adopts a 16-bit wide gain range and
analog and digital I/O boards
9. Thermocouple type: K type, range: Ambient temperature to 1500
degrees Celsius.
10. The data acquisition system can collect data by installing and
starting a data logger or on-site pointer
11. The data acquisition system consists of the following parts
12. Bit thermocouple input module, 16-bit analog input module,
digital input/output module, 12-bit analog output module, 4 and
8-slot base plates, connection sockets, network module, 24-volt 5A
DC universal power supply input, data acquisition computer, printer
|