Sign In | Join Free | My qualitytoyschina.com |
|
Categories | PTC Thermistor |
---|---|
Brand Name: | AMPFORT |
Model Number: | MZ11-08E600~121RM/14D391 |
Certification: | UL |
Place of Origin: | Dongguan,China |
MOQ: | 1000PCS |
Price: | 0.4 USD/PC |
Payment Terms: | T/T |
Supply Ability: | 100,000pcs per week |
Delivery Time: | 10 workdays |
Packaging Details: | Bulk |
Name: | PTC Thermistor |
Coating: | Green Silicone resin |
Lead: | tinned reed |
Rated zero power resistance value: | 60-120Ω±2% |
Rated varistor voltage value: | 390VDC±10% |
Inactive feature: | 40mA △R/Rn≤50% |
Action characteristics: | 150mA ≤120S |
Max withstand voltage: | 500VAC △R/Rn≤30% |
Max operating voltage: | 265VAC |
Curie temperature: | 115±7℃ |
Company Info. |
Dongguan Ampfort Electronics Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Metal Oxide Varistor Built-in Smart PTC Thermistor MZ11-08E600~121RM/14D391 For Nonlinear Power Supply
Description Of The Smart PTC Thermistor
MZ11 type PTC thermistor is mainly assembled in the power input
terminal of microcomputer control panel of various household
appliances, instruments and meters, or in communication lines and
communication equipment for overcurrent, overvoltage, overheating
and lightning protection. This product is also called ten thousand
times fuse or resettable fuse in electronic engineering. Due to its
dual sensitivity to temperature and current, it makes up for the
shortcomings of temperature switches that are not sensitive to
current and conventional fuses that are not sensitive to
temperature. It has the advantages of fast response, strong
protection, and high reliability. Truly high quality and
inexpensive protection components. When used, it can be directly
wound in the transformer wire package or assembled on the circuit
board. The protection principle is: connect it in series in the
load circuit, when the circuit is in normal working state, the
current flowing through the PTC thermistor is not enough to make
the temperature rise exceed the Curie temperature and it is in a
low resistance state, once the circuit fails or When the
overvoltage causes a sudden increase in the current in the circuit,
the resistance of the PTC thermistor increases by 3-4 orders of
magnitude in a short period of time due to self-heating, and the
circuit is cut off in a high resistance state.
When the fault is removed, the PTC thermistor returns to the
original conduction state.
The measured voltage is 220V and 265V, the current flowing through the primary of the transformer, tell us the parameters, and you can send samples for testing,electric energy meter application.
Application Guide Of The Smart PTC Thermistor
1. Our company generally requires the manufacturer to measure the
current flowing through the primary of the transformer at 1.0Un,
1.2Un, and 1.9Un when the transformer is normally loaded with the
PTC thermistor used for the primary overvoltage and overcurrent
protection of the transformer.
2. For the carrier meter, our company requires that the ammeter be
directly introduced into the assembly circuit of the thermistor. 3.
For the three-phase electric meter, our company requires to measure
the current flowing through the primary of the transformer when the
single-phase power supply is 1.0Un, 1.2Un, and 1.9Un.
4. Unless otherwise specified, the default maximum working ambient
temperature of the meter is 70°C. 5. Due to the difference in
technology, instantaneous output power and volume of transformers
that resist 1.9Un for four hours, our company generally does not
recommend manufacturers to use transformers that resist 1.9Un for
four hours.
6. If you replace transformers from different manufacturers or the
same transformer is used on different power boards, our company
recommends that you re-measure relevant parameters and report to
our company for confirmation.
7. If your product requires normal measurement under wide voltage
(110V-440V), please use our company's composite PTC thermistor.
Application circuit Of The Smart PTC Thermistor
Transformer Primary Thermistor Specifications Of The Smart PTC Thermistor
P/N | non-operating current Ih60℃(mA) | Operating current It25℃/300S(mA) | Applicable transformer | ||
1.0Un (mA) | 1.2Un (mA) | 1.9Un (mA) | |||
MZ11-06E201-401RM | 25 | 80 | 15 | 20 | 60 |
MZ11-06E301-601RM | 20 | 70 | 12 | 18 | 50 |
MZ11-06E501-801RM | 15 | 60 | 10 | 12 | 40 |
MZ11-06E701-102RM | 10 | 50 | 6.5 | 8 | 35 |
MZ11-06E901-122RM | 8 | 40 | 5.0 | 6.5 | 30 |
MZ11-06E102-152RM | 6 | 30 | 4.5 | 5.0 | 30 |
MZ11-04B201-401RM | 10 | 35 | 6.0 | 8.0 | 30 |
MZ11-04B401-701RM | 8.5 | 30 | 5.0 | 7.0 | 25 |
MZ11-04B501-801RM | 8 | 30 | 4.5 | 6.5 | 25 |
MZ11-04B801-122RM | 6.5 | 25 | 4.0 | 5.0 | 20 |
MZ11-04B102-122RM | 6.0 | 20 | 4.0 | 4.5 | 18 |
MZ11-08D131-191RM | 25 | 80 | 15 | 20 | 70 |
MZ11-08E151-251RM | 35 | 90 | 25 | 30 | 80 |
MZ11-08E900-161RM | 40 | 120 | 30 | 35 | 110 |
MZ11-08E650-101RM | 50 | 150 | 35 | 40 | 130 |
MZ11-08E450-700RM | 60 | 200 | 40 | 50 | 180 |
MZ11-09E200-400RM | 80 | 250 | 50 | 70 | 200 |
Part Numbering Of The Smart PTC Thermistor
Part number | Normal Operating Voltage | Suitable Meter |
MZ11-06E201-401RM/10D391 | 220±50%AC | single-phase 220V |
MZ11-06E151-251RM/10D391 | 220±50%AC | single-phase 220V |
MZ11-06D500-101RM/10D181 | 100±50%AC | three-phase 100V |
MZ11-08E600-121RM/14D391 | 220±50%AC | 220V large user terminal |
MZ11-10A101-201RM/14D391 | 220±50%AC | 1200VAC solution |
MZ11-10E300-500RM/14D900 | 57.7±50%AC | three-phase 57.7V |
Why should be smart ptc thermistor ?
It has been more than ten years since PTC thermistor was used for
overvoltage protection in the primary stage of the meter
transformer in 1998. Because the use of thermistor has strict
requirements on the parameter matching of the transformer, the
environmental temperature has a great influence on its protection
speed. Many electric energy meter manufacturers are eager to have a
general-purpose PTC thermistor, without considering the size of the
power load, without considering the differences between transformer
manufacturers, without considering the impact of ambient
temperature on the response speed, and meeting all single-phase or
three-phase meters. transformer primary overvoltage requirements
and can just
Locally reduce the impact of surge voltage and group pulse on meter
accuracy. When overvoltage is applied, it responds immediately in a
short time, so that the primary voltage of the transformer is
clamped at about 220V, and the meter works normally. After the
overvoltage is reduced, it will return to the original working
state.
In order to thank many power meter users for their strong support
and help to our company's products over the years, our company
launched a composite PTC thermistor in early 2007. It is used to
solve these problems that electric energy meter enterprises are
plagued by. A PTC thermistor and a varistor (the varistor value
varies according to the rated voltage of the transformer) are
packaged together, and the thermistor responds quickly by using the
current and temperature generated when the varistor is
over-voltage. The effect of the rising resistance of the resistor
on the voltage and current in turn protects the varistor.
protect. Due to the comprehensive protection effect of current and
voltage between the thermistor and the varistor, the
Under the premise that the varistor is damaged, in the design of
this composite PTC thermistor, we have made bold designs on the
varistor's varistor voltage and the thermistor's rated operating
current: it can meet all types of The primary overvoltage
protection of the transformer can also speed up the thermal
overvoltage protection at any ambient temperature.
The response speed of the varistor can also reduce the group pulse,
and the high residual voltage during the surge process affects the
accuracy of the meter. After the protection process is completed,
due to the influence of the heat dissipation of the varistor, the
primary of the transformer can maintain a normal operation of
220±20%. Voltage.
There is no overvoltage of 1.9Un after the composite PTC
thermistor. We only require that the 56 transformer can work at
300VAC for a long time. This is for the transformer that requires a
larger instantaneous power output for the carrier meter. The same
volume can output more power. great power.
In order to verify the reliability of the long-term operation of
the composite PTC thermistor. Since the beginning of 2007, our
company has applied 450V high voltage for 1 minute on the
high-voltage aging life test bench, and the power is turned off for
5 minutes for 1000 hours; in the high temperature aging room at
70℃, the high voltage 450V has been continuously operated for 1000
hours. Among the 200 samples, the thermistor and varistor were all
intact.
About Us Of The Smart PTC Thermistor
AMPFORT is specialized in R&D, manufacturing, application and
sales of PTC thermistors in China.
One of the famous manufacturers for sale. The company currently has
a production plant area of 3,000 square meters, masters a
complete set of mature production processes, has the most
mainstream standard production lines, experienced professionals and
advanced testing equipment, and annually produces and sells 150
million PTC thermistors. above. Technology leadership and
application guidance are the core competitiveness of the company.
At present, the company has dozens of senior technical personnel in
the industry. It has joined hands with the material colleges of
well-known domestic universities to participate in the scientific
and technological research and application projects of PTC
materials for many times. It has stable and mature fans. Body
formula and four patents including composite PTC thermistor with
independent intellectual property rights product. At the same time,
the company also has a large number of professional sales staff,
who have a deep understanding of the application principle of
thermistors, enabling them to provide customers with advanced
application solutions and perfect after-sales service. The company
has passed the ISO9001: 2008 quality system certification. All
products of the company meet the requirements of ROHS. The products
are mainly used in the primary of smart meter power transformer,
485 232 communication interface, IC card interface 4-20mA small
signal interface and relay contact protection and In the protection
circuits such as arc extinguishing control, the company also has
very unique application technology and experience in the protection
circuits of low-power switching power supplies and linear power
supplies. At present, it mainly serves the domestic first-class
intelligent instrument manufacturers. Advanced management
experience, standard production lines and professional production
and R&D personnel ensure that the company's products have
stable first-class quality and better functions, so that customers
can feel better products, more reasonable prices and more intimate
service. It is the unanimous pursuit of every Jinyang member.
AMPFORT hopes to be your seamless partner to create a better future
with you!
![]() |