1Mpa Roots Turbine Flow Meter Aluminum 1600 M3/H Roots Flow Meter

Categories Turbine Flow Meter
Brand Name: NUOYINGJIAYE
Model Number: NYLD-LGQ
Certification: Explosion-proof certificate
Place of Origin: China
MOQ: 1
Price: $300 to $2000
Payment Terms: T/T
Supply Ability: 300 pcs/ pre month
Delivery Time: 7 work days
Packaging Details: Export standard packing
Flow limit: 0~20~1600 m3/h
Nominal pressure: 1.0MPa,1.6MPa
Accuracy: ±1.0%R,±1.5%R
Material: Aluminum allo,Aluminum
Nominal diameter: DN20~DN200
Measured medium temperature: -20℃~60℃
Explosion-proof grade: ExdIIBT6
Protection grade: IP65
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

1Mpa Roots Turbine Flow Meter Aluminum 1600 M3/H Roots Flow Meter


NYLD-LGQ Gas Roots Flowmeter


The NYLD-LGQ gas roots flowmeter has been used as a volumetric meter for more than 100 years. With the features such as high precision, wide range, small volume, light weight, convenient installation and maintenance, reliable and durable service life, it is widely used in natural gas, coal gas, air and other gas flowmeters.It is an ideal flowmeter device for urban gas, oilfield chemical, scientific research and other departments at home and abroad.


NYLD-LGQ Gas Roots Flowmeter Technical Parameters


Model specification

Nominal

diameterDN

mm)


Flow limit (m3/h)


Starting flow m3/h


Pressure

loss at Qmax


Nominal pressure

MPa


Accuracy %


Range


Material

NYLD-LGQ-20A25200.05100

1.0

1.6

1.0

1.5

20:1Aluminum allo
NYLD-LGQ-40A40300.0710030:1
NYLD-LGQ-40B40400.0714040:1
NYLD-LGQ-50A50600.110065:1
NYLD-LGQ-50B50800.114070:1
NYLD-LGQ-80A801000.111070:1
NYLD-LGQ-80B801500.12150120:1
NYLD-LGQ-80C802000.1518070:1
NYLD-LGQ-100A1002500.1118080:1
NYLD-LGQ-100B1003000.11130110:1
NYLD-LGQ-100C1004500.1200110:1
NYLD-LGQ-150A1506500.6535080:1Aluminum
NYLD-LGQ-150B15010000.7645090:1
NYLD-LGQ-200A20016001.1550053:1

NYLD-LGQ Gas Roots Flowmeter Operating Principle


(1).The flowmeter consists of 5 parts (see Figure 1)



(2).Intelligent gas roots flowmeter working principle (see Figure 2)

The intelligent gas roots flowmeter consists of a housing, a conjugate rotor and an intelligent flow totalizer. Under the action of the pressure difference between the inlet and outlet of the circulating gas (P inlet>P>outlet),the pair of conjugate maintain the correct relative position of the rotor through the precision-machined adjusting gear.The optimum working gap between the rotor, the rotor and the housing, and the rotor and the wall plate achieves a continuous non-contact seal.



For each revolution of the rotor,it outputs four times theeffective volume of the metering chamber, and the number of revolutions of the rotor is transmitted to the intelligent flow totalizer through the magnetic sealing coupling device and the speed reducing mechanism, to display the cumulative volume of the output gas. (The figure shows only a quarter cycle).


(3).Intelligent flow totalizer working principle

The intelligent flow totalizer consists of temperature and pressure detection analog channel, flow sensor channel and microprocessor unit, and is equipped with an external signal interface to output various signals. The microprocessor in the intelligent flow totalizer performs temperature and pressure compensation and compression factor correction according to the gas equation. The gas equation is as follows:

Where:

Qn: volume flow rate under standard condition (m3/h);

Qg: volume flow rate under working condition (m3/h);

Pg: meter pressure at the flowmeter pressure detection point (KPa)

Pa: local atmospheric pressure (KPa);

Tg: absolute temperature(273.15 + t) (K) of the medium;

t: measured medium temperature (°C);

Zn: compression factor under standard condition;

Zg: compression factor under working condition;

Tn: absolute temperature (273.15+20) (K) under standard state;

Pa: local atmospheric pressure (KPa);

Pn: standard atmospheric pressure (101.325KPa);

P: P = Pa + Pg.

Note:For natural gas Zn/Zg=Fz2, Fz is called super compression factor. This product is calculated according to the formula of SY/T6143-1996 of CNPC standard.


Cheap 1Mpa Roots Turbine Flow Meter Aluminum 1600 M3/H Roots Flow Meter for sale