Sign In | Join Free | My qualitytoyschina.com
qualitytoyschina.com
Products
Search by Category
Home > Flow Meters >

Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS

Categories Ultrasonic Flow Meters
Brand Name: Purescience
Model Number: YE-TUF2000SWP
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin: China
MOQ: 5 sets
Price: USD150-USD900
Supply Ability: 500 sets per month
Delivery Time: 3 weeks
Packaging Details: carton
Product name: Doppler Ultrasonic flow meter
Type: wall mount, insertion type
Accuracy: + / - 1%FS
Operation: Key boards
Output signal: 4-20 mA / OCT pulse / relay
Input: 3-way 4-20 mA (temperature, pressure and level)
Communication: RS485 / Modbus
Power supply: 8-36 VDC / 10-30 VAC
Pipe diameter: 15 mm - 6000mm
Pipe mount Material: weld steel, stainless steel, cast iron, copper / brass, cement pipe, aluminum
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS

    Doppler wall mount ultrasonic Doppler flow meter, pipe type for pulp and paper | accuracy 1% FS


    Generals

    The wall mount ultrasonic doppler flowmeters , can measure the flow of liquids that contain sound reflectors, suspended solids, or gas bubbles larger than 100 microns. It can automatically adjust filtering and gain settings to produce reliable readings in a wide range of liquid and reflector conditions.

    The flowmeters transmitt ultrasonic sound through the pipe wall, or from the probe inserted into the flowing liquid by the piezoelectric crystals contained in the transducer and probe tip. The sound wave, then be reflected by sonic reflectors suspended in the liquid, also recorded by the receiver. In case the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted, that's Doppler frequency, from the transmitted frequency. The difference between the 2 frequencies is directly proportional to the speed of the sonic reflectors, resulting in a liquid flow rate that is converted to various user-defined units.


    Data sheet

    Contents

    Technical parameters

    Data convertor

    Work Principle

    Doppler or transit-time ultrasonic flow meter

    Precision

    + 1%

    Panel

    4 keys panel

    Signal output

    single channel 4-20mA, resistance 0-1K , accuracy 0.1%

    single way OCT pulse (Pulse width: 6-1000ms, default: 200ms)

    single channel relay output

    Signal input

    Tri-way 4-20mA, accuracy: 0.1%, (temp., pressure, level)

    Temp. sensor Pt100, heat / energy measurement

    Interface

    Galvanic isolation RS485, software upgrade by PC, MODBUS

    Cable for signal

    Paired cable, 50m; RS485, transmission distance 1000m or above.

    Port connection

    Suitable pipe

    Steel, stainless, cast iron, copper, cement, PVC, aluminum, etc

    Diameter

    DN15 - DN6000 mm

    Pipe straight

    Upstream: 10 D, downstream: 5 D, (30xDia from pump or valve)

    Measurement

    Media to measured

    Liquid is single sonic wave transmittable, such as municipal tap water, cooling

    water,seawater, waste water, pure water, sewage with particle content, oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals, heating, ventilation air conditioner, power plant


    Media temp.

    -30-160℃


    Turbidity

    Up to 10000 ppm and less bubble


    Flow rate

    0-7 m/s

    Work environment

    Temp.

    Transducer: -30-160℃, Convertor: -20-60 ℃,

    Humidity

    Transducer: submersible up to depth 2m, Convertor: 85%RH,

    Power supply

    DC8-36V or AC10-30V / 1.5W

    Dimension

    Convertor: 95*95*35mm


    Description:

    Its configuration includes the front-panel keypad, multi-line backlit LCD ( flow rate and total in user-selected units display). Power supply options include AC and DC. Output signal options are: 4 to 20 mA, relays, pulse.

    Transducers available with clamp-on and non-intrusive transducer for most metal or plastic pipes, high temperature and protection class. The operator can place these clamp-on transducers up to 305 m from the converter. The insertion probe transducer should be used on piping systems that do not permit ultrasonic penetration. It's inserted into the pipe wall and comes into direct contact with the flowing liquid.

    • Non-invasive clamp technology
    • Easy to install
    • No moving parts, leakage or corrosion, therefore no pressure drop
    • No pipe cutting or process interruption
    • Measurement independent of fluid properties
    • Bi-directional flow measurement

    Metering Diagram

    Flow measurement Heat measurement

    Reference chart

    Type

    Model

    Pipe dia (mm)

    Temperature

    Dimension (mm)

    Clamp on

    TS-2

    DN15-100

    -30-90℃

    45x25x32

    TM-1

    DN50-700

    -30-90℃

    64x39x44

    TL-1

    DN300-6000

    -30-90℃

    97x54x53

    Clamp on (high temperature)

    TS-2-HT

    DN15-100

    -30-90℃

    45x25x32

    TM-1-HT

    DN50-700

    -30-90℃

    64x39x44

    TL-1-HT

    DN300-6000

    -30-90℃

    97x54x53

    Insertion type

    TC-1

    DN80-6000

    -30-90℃

    190x80x55

    TC-2(lengthen)

    DN80-6000

    -30-90℃

    335x80x55

    Pipe type

    G3 (π type)

    DN15-25

    -30-160℃


    G2

    DN32/DN40

    -30-160℃


    G3

    DN50-6000

    -30-160℃



    Optional temperature transducer

    Specification

    Model

    Dia

    Temp.

    Water cut

    Accuracy

    Clamp-on temp. transducer Pt100

    CT-1

    >DN50

    -40-160℃

    No

    100+ 0.8℃

    Insertion temp. Transducer Pt100

    TCT-1

    Yes

    Insertion temp. Pt100 with pressure

    PCT-1

    No

    Insertion temp.Pt100 for small pipe D

    SCT-1

    <DN50

    Yes


    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Applications

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    I

    Model









    YF

    Electromagnetic flowmeter


    TF

    Turbine


    VF

    Votex


    LX

    Vane wheel


    T

    Ultrasonic



    E/F display mode

    E: compact/local display, F: remote display




    Pipe Dia

    Type (mm)




    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

    400, 500, 600, 800, 1000




    Code

    Accuracy




    1

    + 0.5% FS




    2

    + 1.0% FS




    3

    + 0.2% FS





    Code

    Type





    N

    Converter: 12 / 24 VDC, pulse output





    A

    Transmitter: 24VDC, 4-20mA outpt





    B

    Intelligent, Lion battery, no local display





    G

    Smart, local display, 4-20mA output





    C1

    Smart, local display, RS485





    C2

    Smart, local display, HART






    Code

    Type






    S

    Carbon steel housing






    L

    Stainless steel housing






    G

    High pressure housing






    HL

    316L electrode






    HTi

    Titanium electrode






    HTa

    Tantlum electrode






    HC

    Hastelloy-C electrode






    L1

    Liquid media






    L2

    Gas media






    P

    Pressure compensation






    T

    Temperature compensation






    PT

    Pressure&Temp. Compensation






    F

    PTFE liner






    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F,

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

    RS485, 316L electrode, liquid media meter, PTFE liner


    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Calibration

    Work shop

    Product Tags:

    magnetic flowmeter

      

    liquid flow meter

      
    Cheap Pulp And Paper Magnetic Flow Meter Insertion Type Accuracy 1% FS for sale
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0